Skip to main content

Flow Cytometry Immune Monitoring Shared Resource

RRID:SCR_023432

Samples & Containers

Samples for the FACScanto II and the LSR II must be provided in 12x75mm polystyrene BD brand Falcon tubes. The only tubes compatible with these analyzers are:

  • Cat. # 35-2052 - sterile, no cap, 125/bag
  • Cat. # 35-2054 - sterile, with cap, 125/bag
  • Cat. # 35-2058 - sterile, with cap, 25/bag
  • Cat. # 35-2008 - nonsterile, no cap, 1000 bulk
  • Cat. # 35-2235 - sterile, with cell strainer, 25/bag

Samples for the FACSAria may be provided in 12x75mm polystyrene tubes or 15ml conical tubes.

The recommended sample concentration for the FACScanto II and the LSR II is 1x106 cells per ml in PBS (no Mg++, Ca++ or serum) or fixative.

1-3% paraformaldehyde is the recommended fixative for most cell types.

The recommended sample concentration for the FACSAria is 3x106-5x106 cells per ml in PBS (no Mg++, Ca++ or serum) or fixative.

Pathogenic samples or live samples derived from human sources must be approved by the Facility Manager. When bringing samples for multi-parameter analysis, single positive controls must be provided for each color user.

Policy

Cell Suspensions

Cell suspensions are typically prepared in the investigator's laboratory and brought to the Cytometry Core Facility ready to be run. There is a wet lab available in the facility with limited equipment for use in the preparation of samples, if needed.

Policy

Cryo-preservation

We are able to assist with a number of cryo-preservation techniques suitable for uses such as CyTOF, flow cytometry and functional assays.

Service

Magnetic cell separation

We use Miltenyi MACS magnetic cell separation. This can be performed on human or mouse tissues.

Service

Tissue dissociations & Bone marrow extractions

Extracting cells from solid tissue (e.g., tumors, spleen, lymph nodes, etc.) for flow cytometry requires skill with tissue dissociation, we can help.

Collecting useful cells for analysis from bone marrow can be tricky, but we are here to assist.

Service

Metabolic assays (Seahorse XFe96)

The Agilent Seahorse XFe96 can be used to perform metabolic assays such as; mitochondrial function, ATP rate, Cell energy phenotype, Glycolytic rate and more. Ask for more details.

Service

Complex immune assays

Our Shared Resource can provide the needed instrumentation, expertise and support for assays such as: T cell proliferation & activation, ELISA, functional phenotyping, genomic immune profiling and more. Ask for more details.

Service
Contact